v23990-k220-a-pm preliminary datasheet miniskiip ? 2nd gen. pim size 2, 1200v / 35 a v23990-k220-a-01-19 output inverter application general conditions: 3 phase spwm, vgeon= 15 v rgon= 28 ohm rgoff = 28 ohm vgeoff= -15 v figure 1. typical avarage static loss figure 2. typical avarage static loss as a function of output current as a function of output current igbt ploss=f(iout) fred ploss=f(iout) conditions: tj=125c conditions: tj=125c modulation index * cosfi modulation index * cosfi parameter mi*cosfi from -1,00 to 1,00 parameter mi*cosfi from -1,00 to 1,00 in 0,20 steps in 0,20 steps figure 3. typical avarage switching loss figure 4. typical avarage switching loss as a function of output current as a function of output current igbt ploss=f(iout) fred ploss=f(iout) conditions: tj=125c conditions: tj=125c dc link= 600 v dc link= 600 v switching freq. fsw from 2 khz to 16 khz switching freq. fsw from 2 khz to 16 khz parameter in * 2 steps parameter in * 2 steps 0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40 iout (a) ploss (w) mi*cosfi=1 mi*cosfi=-1 0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40 iout (a) ploss (w) mi*cosfi=1 mi*cosfi=-1 0,0 10,0 20,0 30,0 40,0 50,0 60,0 70,0 80,0 0 5 10 15 20 25 30 35 40 iout (a) ploss (w) fsw=16khz fsw=2khz 0,0 2,0 4,0 6,0 8,0 10,0 12,0 14,0 16,0 0 5 10 15 20 25 30 35 40 iout (a) ploss (w) fsw=16khz fsw=2khz miniskiip is a trademark of semikron. semikron is a trademark. tyco is a trademark. copyright by tyco electronics finsinger feld 1, d-85521 ottobrunn page1 power.switches@tycoelectronics.com copyright by vincotech revision:1
v23990-k220-a-pm preliminary datasheet miniskiip ? 2nd gen. pim size 2, 1200v / 35 a v23990-k220-a-01-19 output inverter application general conditions: 3 phase spwm, vgeon= 15 v rgon= 28 ohm rgoff = 28 ohm vgeoff= -15 v figure 5. typical available 50hz output current figure 6. typical available 50hz output current as a function of mi*cosfi as a function of switching frequency phase iout=f(mi*cosfi) phase iout=f(fsw) conditions: tj=125c conditions: tj=125c dc link= 600 v dc link= 600 v fsw= 4 khz mi*cosfi= 0,8 heatsink temp. th from 60 c to 100 c heatsink temp. th from 60 c to 100 c parameter in 5 c steps parameter in 5 c steps figure 7. typical available 50hz output current figure 8. typical available 0hz output current as a function of mi*cosfi and fsw as a function of switching frequency phase iout=f(fsw,mi*cosfi) phase ioutpeak=f(fsw) conditions: tj=125c conditions: tj=125c dc link= 600 v dc link= 600 v th= 80 c heatsink temp. th from 60 c to 100 c parameter in 5 c steps th=60c th=100c 0 5 10 15 20 25 30 35 40 45 50 -1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 mi*cosfi iout (a) th=60c th=100c 0 5 10 15 20 25 30 35 40 45 50 1 10 100 f sw (khz) iout (a) th=60c th=100c 0 5 10 15 20 25 30 35 40 45 50 1 10 100 f sw (khz) iout (apeak) 12481632 -1 -0,8 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 1 iout (a) 38,008-42,009 34,007-38,008 30,006-34,007 26,005-30,006 22,004-26,005 18,003-22,004 14,002-18,003 10,001-14,002 6-10,001 mi* cos fi fsw miniskiip is a trademark of semikron. semikron is a trademark. tyco is a trademark. copyright by tyco electronics finsinger feld 1, d-85521 ottobrunn page2 power.switches@tycoelectronics.com copyright by vincotech revision:1
v23990-k220-a-pm preliminary datasheet miniskiip ? 2nd gen. pim size 2, 1200v / 35 a v23990-k220-a-01-19 output inverter application general conditions: 3 phase spwm, vgeon= 15 v rgon= 28 ohm rgoff = 28 ohm vgeoff= -15 v figure 9. typical available electric figure 10. typical efficiency peak output power as a as a function of output power t function of heatsink temperature inverter pout=f(th) inverter efficiency=f(pout) conditions: tj=125c conditions: tj=125c dc link= 600 v dc link= 600 v modulation index mi= 1 modulation index mi= 1 cosfi= 0,80 cosfi= 0,80 switching freq. fsw from 2 khz to 16 khz switching freq. fsw from 2 khz to 16 khz parameter in * 2 steps parameter in * 2 steps figure 11. typical available overload factor as a function of motor power and switching frequency inverter ppeak/pnom=f(pnom,fsw) conditions: tj=125c dc link= 600 v modulation index mi= 1 cosfi= 0,8 switching freq. fsw from 1 khz to 16 khz parameter in * 2 steps heatsink temperature= 80 c motor efficiency= 0,85 0,0 5,0 10,0 15,0 20,0 25,0 60 65 70 75 80 85 90 95 100 th ( o c) pout (kw) fsw=16khz fsw=2khz 94,0 95,0 96,0 97,0 98,0 99,0 100,0 0,0 4,0 8,0 12,0 16,0 20,0 pout (kw) efficiency (%) fsw=16khz fsw=2khz switching frequency (khz) 100 150 200 250 300 350 400 motor nominal power (hp/kw) overload (%) 1 1412 1059 706 424 282 212 141 2 1308 981 654 392 262 196 131 4 1121 841 560 336 224 168 112 8 847 635 424 254 169 127 16 541 406 271 162 1,50 / 1,10 2,00 / 1,47 3,00 / 2,21 5,00 / 3,68 7,50 / 5,52 10,00 / 7,36 15,00 / 11,03 miniskiip is a trademark of semikron. semikron is a trademark. tyco is a trademark. copyright by tyco electronics finsinger feld 1, d-85521 ottobrunn page3 power.switches@tycoelectronics.com copyright by vincotech revision:1
|